PENGARUH V ARIASI PEMASANGAN HEAT EXCHANGERSPADAREFRIGERATORTERHADAP KAPASIT AS PENDINGINAN DAN LAJU ALIRAN MASSA REFRIGERAN

Ega Taqwali Berman

Abstract


This study aims to compare the effect of variations in the refrigerator heat exchanger installation of
cooling capacity and refrigerant mass flow rate. Tests performed on the test section consists of two
types of heat exchangers, Suction-Liquid Heat Exchanger (SLHX) and Tube in Tube Heat Exchanger
(TiTHX). Test data measured at the temperature of the cooling load temperature of 60C to - 60C and
the working fluid is used as a cooling medium is a refrigerant 12. As a result, it was obtained that in
this research was cooling capacity by a refrigeration system that uses TiTHX 0.6% greater than the
refrigeration system that uses SLHX. This is due to there is little difference between the temperature of
evaporation and temperature liquid refrigerant that will go into the expansion device on a system that
uses TiTHX than refrigeration systems that use SLHX. The amount of refrigerant is circulated 0.6%
less on a system that uses TiTHX than systems that use SLHX.


Keywords


refrigerator, heat exchangers, cooling capacity, refrigerant

Full Text:

PDF

References


ASH RAE Refrigeration Handbook, American

Society of Heating, Refrigerating, and Air-

Conditioning Engineers,. 1998. ISBN 1-

-54-0, Chapter 2.

Cengel YA, Boles MA. 2006. Thermodynamics:

An Engineering Approach. 5th ed. McGraw-

Hill.

(3] Domanski PA, Didion DA. 1994. Evaluation of

suction-line/liquid-line heat exchange in the

refrigeration cycle. International

Refrigeration Conference 17: 487-493.

(4] Dossat, R.J. 1961. Principles of Refrigeration,

John Wiley & Sons, Inc.New York and

London.

Handoyo EA, Lukito A. 2002. Analisis pengaruh

pipa kapiler yang dililitkan pada line suction

terhadap performansi mesin pendingin.

Jurnal Teknik Mesin. Vol. 4: 94 - 98.

Klein S.A., Reindl D.T., Brownell K., 2000,

Refrigeration system performance using

liquid-suction heat exchangers, lnt.J.

Refrigeration. Vol. 23: 588-596.

Mastrullo R, Mauro A.W., Tino S., Vanoli G.P.,

, A chart for predicting the possible

advantage of adopting a suction/liquid heat

exchanger in refrigerating system, J. Applied

Thermal Engineering 27: 2443-2448.

Hermanto A., Suwono, A., Abdurrochim, Pasek

A.O., 2005, Pengembangan Met ode

Simulasi Sistem Pengkondisian Udara Energi

Surya, J. Teknik lllesin, Vol. 20, No.2.

Hermawan A. 2011. HVAC dan Refrigerasi

Tutorial, Tersedia di:

http:// citra pel a ngi nu sa nta ra. b I ogspot. com,

diunduh 31.10.2011, pk.11.10 am.


Article Metrics

Abstract view : 63 times
PDF - 107 times

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.