PENGARUH V ARIASI PEMASANGAN HEAT EXCHANGERSPADAREFRIGERATORTERHADAP KAPASIT AS PENDINGINAN DAN LAJU ALIRAN MASSA REFRIGERAN
Abstract
This study aims to compare the effect of variations in the refrigerator heat exchanger installation of
cooling capacity and refrigerant mass flow rate. Tests performed on the test section consists of two
types of heat exchangers, Suction-Liquid Heat Exchanger (SLHX) and Tube in Tube Heat Exchanger
(TiTHX). Test data measured at the temperature of the cooling load temperature of 60C to - 60C and
the working fluid is used as a cooling medium is a refrigerant 12. As a result, it was obtained that in
this research was cooling capacity by a refrigeration system that uses TiTHX 0.6% greater than the
refrigeration system that uses SLHX. This is due to there is little difference between the temperature of
evaporation and temperature liquid refrigerant that will go into the expansion device on a system that
uses TiTHX than refrigeration systems that use SLHX. The amount of refrigerant is circulated 0.6%
less on a system that uses TiTHX than systems that use SLHX.
Keywords
Full Text:
PDFReferences
ASH RAE Refrigeration Handbook, American
Society of Heating, Refrigerating, and Air-
Conditioning Engineers,. 1998. ISBN 1-
-54-0, Chapter 2.
Cengel YA, Boles MA. 2006. Thermodynamics:
An Engineering Approach. 5th ed. McGraw-
Hill.
(3] Domanski PA, Didion DA. 1994. Evaluation of
suction-line/liquid-line heat exchange in the
refrigeration cycle. International
Refrigeration Conference 17: 487-493.
(4] Dossat, R.J. 1961. Principles of Refrigeration,
John Wiley & Sons, Inc.New York and
London.
Handoyo EA, Lukito A. 2002. Analisis pengaruh
pipa kapiler yang dililitkan pada line suction
terhadap performansi mesin pendingin.
Jurnal Teknik Mesin. Vol. 4: 94 - 98.
Klein S.A., Reindl D.T., Brownell K., 2000,
Refrigeration system performance using
liquid-suction heat exchangers, lnt.J.
Refrigeration. Vol. 23: 588-596.
Mastrullo R, Mauro A.W., Tino S., Vanoli G.P.,
, A chart for predicting the possible
advantage of adopting a suction/liquid heat
exchanger in refrigerating system, J. Applied
Thermal Engineering 27: 2443-2448.
Hermanto A., Suwono, A., Abdurrochim, Pasek
A.O., 2005, Pengembangan Met ode
Simulasi Sistem Pengkondisian Udara Energi
Surya, J. Teknik lllesin, Vol. 20, No.2.
Hermawan A. 2011. HVAC dan Refrigerasi
Tutorial, Tersedia di:
http:// citra pel a ngi nu sa nta ra. b I ogspot. com,
diunduh 31.10.2011, pk.11.10 am.
Article Metrics
Abstract view : 78 timesPDF - 124 times
Refbacks
- There are currently no refbacks.
This work is licensed under a Creative Commons Attribution 4.0 International License.